WEG MTW04 Medium Voltage Switchgear

Technical Specification

Features:
  • Make: WEG
  • Model code: MTW04
  • Type: Medium-Voltage Switchgear
  • Max. Voltage: 17.5 kV
  • Max. Current: 4000 A
Read more
Additional info:

The Distribution and Control Switchgear are developed and manufactured and type tested according to IEC 62271-200 Several device combination options, meeting the customers´ needs and requirements Fast withdrawable circuit breaker/contactor replacement using the cart for transportation and installation Fast and easy expansion due to its modular design Reduced maintenance Easy access to the compartments for maintenance by means of removable covers and doors Interlock system against incorrect operations High safety level for the operators, being all the main circuit breaker operations done with the medium voltage door closed Air-insulated Distribution and Control Switchgear with reduced dimensions, allowing a smaller electric room No need for handling insulating gases or pressure supervision Quality certification as per ISO 9001 Metal enclosure and grounded separators Distribution and Control Switchgear with internal arc rating according to IEC, with front, side and rear access, for all the short-circuit currents

Read more
Make WEG
Manufacturer WEG
Category Transmission and Distribution>Switchgears
Model code MTW04
Type Medium-Voltage Switchgear
Max. Voltage 17.5 kV
Max. Current 4000 A
No. of Phases 3
Standards IEC 62271-200
Protection IP-4X
Additional info
  • The Distribution and Control Switchgear are developed and manufactured and type tested according to IEC 62271-200
  • Several device combination options, meeting the customers´ needs and requirements
  • Fast withdrawable circuit breaker/contactor replacement using the cart for transportation and installation
  • Fast and easy expansion due to its modular design
  • Reduced maintenance
  • Easy access to the compartments for maintenance by means of removable covers and doors
  • Interlock system against incorrect operations
  • High safety level for the operators, being all the main circuit breaker operations done with the medium voltage door closed
  • Air-insulated Distribution and Control Switchgear with reduced dimensions, allowing a smaller electric room
  • No need for handling insulating gases or pressure supervision
  • Quality certification as per ISO 9001
  • Metal enclosure and grounded separators
  • Distribution and Control Switchgear with internal arc rating according to IEC, with front, side and rear access, for all the short-circuit currents
Download PDF version Download PDF version