Eaton EBMBD FD S756V W10360 EBM explosion-proof disconnect switches
Technical Specification
- Make: Eaton
- Model code: EBMBD FD S756V W10360
- Type: Non-fused
- Application: Hazardous/Classified Locations
- Rated current: 100 A
Crouse-Hinds series EBM Explosion-proof Disconnect Switches are used to disconnect motors, lighting and other circuits in locations made hazardous by the presence of flammable gases or vapours or ignitable dusts. Certified for use in Class I and Class II hazardous areas, EBM disconnect switches are also NEMA 4X rated for use indoors or outdoors in damp, wet and dirty locations where frequent washdowns, heavy rain or water spray is prevalent. Features: Rugged corrosion-resistant cast copper-free aluminium construction (less than 0.4 of 1%) Switch operating handle is located through the right side wall of the body, permits visual confirmation of correct alignment and operation Total compliance to the wiring end room requirements of the National Electrical Code® Semi-clamshell enclosure design, with an external flanged ground joint between body and cover makes interior components more accessible Minimum enclosure-to-enclosure spacing with little interference between the opened cover and an adjacent enclosure Stainless steel hinges allow the cover to swing well out of the way Stainless steel quick release captive hex head cover bolts; stainless steel springs provide clear indication that cover bolts are fully retracted from the body Switch operating handle can be padlocked in either the "ON" or "OFF" position Neoprene cover gasket permanently attached to the cover seals out moisture Bodies have top and bottom drilled and tapped conduit entrances for power and conduits; removable reducers are supplied as standard, to accommodate smaller size conduits; all conduit entrances are plugged Tap-on mounting feet
Read moreMake | Eaton |
---|---|
Manufacturer | Eaton |
Category | Motors and Electrical Equipment>Safety Switches and Disconnects |
Model code | EBMBD FD S756V W10360 |
Type | Non-fused |
Application | Hazardous/Classified Locations |
Rated current | 100 A |
No. of Phases | Polyphase |
Power rating | 25 HP/30 HP/75 HP |
Rated Voltage | 200-600 Vac / 250 Vdc |
Nema type | 4, 7, 3R, 12, 3, 9 |
Construction | Copper-free aluminium |
Standard | NEC/CEC |
Weight | 52 Kg |
Additional info |
Crouse-Hinds series EBM Explosion-proof Disconnect Switches are used to disconnect motors, lighting and other circuits in locations made hazardous by the presence of flammable gases or vapours or ignitable dusts. Certified for use in Class I and Class II hazardous areas, EBM disconnect switches are also NEMA 4X rated for use indoors or outdoors in damp, wet and dirty locations where frequent washdowns, heavy rain or water spray is prevalent. Features:
|